RGXLED is a professional China Bus And Taxi 12V To 5V Led Display Power Supply manufacturers and suppliers, if you are looking for the best Bus And Taxi 12V To 5V Led Display Power Supply with low price, consult us now!
Find a huge selection of Bus And Taxi 12V To 5V Led Display Power Supply from China at RGXLED.
Product Name: slim switching power supply
Part Number: RGX-CAR-100-5
This product is DC-DC non-isolated constant voltage power supply device, suitable for DC power supply system, such as the on-board display, etc.. , has the characteristics of high efficiency, small size, stability and high reliability; Embedded company's unique patented technology: anti-reverse circuit, power supply with a variety of perfect protection functions, such as output short circuit, overvoltage protection...
Input Electrical Characteristics
Model |
YY-CAR-5 |
Normal output power |
100W |
Normal voltage range |
12Vdc OR 24Vdc |
Intput voltage range |
10Vdc~30Vdc |
Frequency range |
- |
PF |
- |
Leakage Current |
≤0.025ma,@30Vdc |
Max intput ac current |
12A |
Inrush current |
- |
Efficiency(full load) |
10~15Vdc≥94%;16~30Vdc≥92% |
Operate voltage rating Cuidline
Operate temperature rating Cuidline.
Output viltage curve
Output voltage & Current Regulation
Model |
YY-CAR-5 |
Output Voltage |
5Vdc |
Setting |
±0.1V |
Output Rated Current |
20A |
Peak Current |
22A |
Regulation |
±3% |
Power on delay time
delay time Output Voltage |
220Vac Intput @ -40~-5℃ |
220Vac Intput @≥25℃ |
5Vdc |
≤2S |
≤1S |
Output Transient Response
Slew Rate |
Voltage Limit |
Load Change |
|
5Vdc |
1~1.5A/uS |
≤±5% |
@Min.to 50% load and 50% to max load |
DC output voltage rise time
Output Voltage |
12Vdc or 24Vdc input & full load |
Note |
5Vdc |
≤50mS |
The rise time measured is when the output voltages rise from 10% to 90% of specified output voltage Vout observed on the channel waveform. |
DC Output Ripple & Noise
Output Voltage |
Ripple & Nnoise |
5Vdc |
80mVp-p@25℃ |
140mVp-p@-25℃ |
Note
Ripple & Nnoise test:Ripple & Nnoise bandwidth is set to 20mHZ.
Use a 0.1uf ceramic capacitor in parallel with a 10uf eaectrolyic capacitor at output connector terminals for ripple & noise measurements.
DC Output Short Circuit Protection
Output Voltage |
Comments |
5Vdc |
Output will be stopped when the circuit is shorted and restart operating after eliminating malfunction |
DC Output Over Load Protection
Output Voltage |
Comments |
5Vdc |
Output will be stopped when the DC current is more than 105~118% of rated current and restart operating after eliminating malfunction |
Over temperature Protection
Output Voltage |
Comments |
5Vdc |
Output will be stopped when the temperature reaches the set value and restart operating after eliminating malfunction |
Dielectric Strength
(Input To Output) |
- |
(Input To FG) |
- |
Insulation Resistance
Output To FG |
DC 500V 10MΩMin (at room temperature) |
Input To FG |
DC 500V 10MΩMin (at room temperature) |
EMI
Note:RGX power can word together with customer to modify the power and the system to meet above criterion
EMS
A. Electrostatic immunity ESD
*GB17626.2-1998/IEC61000-4-2 Lever 3 A
B. Voltage sag DIP
*GB17626.11-1998/IEC61000-4-11
Temperature
Operating:-40℃~+60℃
Note: The power can power on and work @ -40℃
Storage:-40℃to+70℃
Operating: From 15RH to 90RH relative humidity(non-condensing).
Operating: From 5RH to 95RH relative humidity(non-condensing).
Altitude
Operating:0 to 3000m
Impact resistance: 49m/s2(5G),11ms,once each X,Y and Z axis.
Vibration resistance: 10-55Hz,19.6m/s2(2G),20minutes each along X,Y and Z axis.
Natural cooling
Custom should avoid to place obstacle inside the 5cm of product surrounding in order to push cooling itself, because the product is cooled by natural air through the Aluminum Alloy Cabinet.
Specific cautions
The product should be suspended in air or placed on the face of metal when assembled, and be avoided to place on the face of non-conducting heat materials such as, plastics, board and so on.
The space between each module should be exceeded 5cm in order to avoid affecting cooling of each other
The MTBF shall be at least 50,000 hours at 25℃,full load and normal input condition.
Weight:208g
The figure below is vertical view of product, Input 4 pin terminal block is on the left side and Output 6 pin terminal block is on the right side.
Table 1 : Input 4 pin terminal block (pitch 9.5mm)
Name |
Function |
IN+ |
The DC Input positive pole |
IN- |
The DC Input negative pole |
Table 2:Output 6 pin terminal block(pitch 8.25mm)
Current through the output terminal block should not exceed 15A, so never overload test and work in that kind of condition. Or the terminal block will be damaged because of high temperature.
Name |
Function |
V+ |
Output DC positive pole |
V- |
Output DC negative pole |
Outside dimension : L*W*H=115×70×25mm
The figure below is mounting hole position
Unit:mm
Tip: The above figure shows the position map of the bottom shell installation hole
Method 1.--.
Method 2. M3 screws lock in the mounting rack of 4 U grooves under the cabinet.
One way should be chosen from the two methods, make sure that the part of screw that is in the body of power supply should be less than 3mm and exert not much strength to avoid damaging the screw.
The power supply must work at the condition of insulation and terminal post of cable have to go through the insulation treatment. Besides, make sure the product is grounded well and forbid touching the cabinet in order to avoid scalding hand.
Packaging: The Product name, Model, Manufacturer mark, Inspection certificate from manufacturers quality department and production data should be recorded in the manifest which is inside the package.
Transport: the car transport, shipment, aircraft transport is suitable and make sure that the products are under the condition of sunscreen and waterproof. The products should handle with care when loading or unloading.
Storage: It will be better that the product store in the environment temperature between -10℃and +80℃as well as the humidity less than 80%RH. Make sure that there is no corrosive gases in the store environment. Besides, the surrounding must not have the strong mechanical vibration and high-intensity magnetic field. And the case have to be block up at least 25cm away from the earth. The regulation mentioned above will let the products store for 2 years, power supply should be tested after 2 years.